Project
Report type
Standards
Scope & outputs
5Data review

Connect a TabLogs project

Auger pulls boreholes, lab results, QA flags and figures live from TabLogs — using your TabLogs access permissions.

Riverside Development, Stage 2
#4271 · 14 Quarry Rd, Brisbane QLD · updated yesterday
6 boreholes23 lab tests2 QA flags4 figures
Westfield Substation Upgrade
#4259 · Ipswich QLD · updated 4 days ago
11 boreholes41 lab tests0 QA flags
Coastal Rd Pavement Investigation
#4233 · Gold Coast QLD · lab pending
9 boreholes⚠ lab incomplete

Report type & section outline

Each report type is trained separately from your firm's examples — pick the type, then adjust this report's outline.

DSI Interpretive
trained on 3 examples · ready
9 sectionsper-section guidance ✓
Pavement Investigation
trained on 1 example · usable
7 sectionsgeneric guidance in places
Contamination Assessment
⚠ low confidence — 1 example · add 2 more in Settings
drafting enabled, flagged

Outline for this report — from the DSI Interpretive type (firm voice applies on top). Add, remove or reorder.

Confirm applicable standards

Defaults from your profile for Australia · QLD. Your confirmation is recorded — these selections appear in the report and audit trail.

AS 1726-2017
Geotechnical site investigations
firm default
AS 2870-2011
Residential slabs and footings — site classification
firm default
AS 3798-2007
Guidelines on earthworks for commercial and residential developments
firm default
AS 4678-2002
Earth-retaining structures
No retaining structures in scope — excluded

Scope, outputs & appendices

Context the assistant uses for every section, plus what gets attached to the deliverable.

Appendices — rendered by TabLogs, attached by Auger

Appendix A — Borelogs
6 logs · TabLogs borelog renderer · template "Firm A4 v3"
Appendix B — Laboratory certificates
23 tests · from TabLabs LIMS
Appendix C — Site plan & fence diagram
Site plan v4 · fence A–A′ · print resolution
Appendix D — Photo log
18 photos available

Data review — confirm what Auger extracted

Nothing is drafted until you confirm these inputs. QA flags come from your TabLogs rule packages, run live against this project.

6
boreholes
21
strata records
23
lab tests
4
groundwater obs
2
QA flags
BoreholeDepthStrataIn-situLabQA
BH0112.5 m4 unitsSPT ×5✓ 4 tests
BH0215.0 m5 unitsSPT ×6✓ 5 tests
BH039.0 m3 unitsSPT ×3⚠ no lab results
BH0412.0 m4 unitsSPT ×5✓ 6 tests⚠ QA-12: PI=45 > bound 35
BH0510.5 m3 unitsSPT ×4✓ 4 tests
BH0611.0 m4 unitsSPT ×5✓ 4 tests⚠ QA-07: SPT refusal anomaly
⚠ Gaps Auger will disclose in the report BH03 has no laboratory results · groundwater observed in 2 of 6 boreholes only · single monitoring round (seasonal variation uncharacterised)
Confirm inputs → open workspace